101 Laser Protective Filter
OD Specifications (Optical Density):
OD 7+ @ 190-285 nm
OD 6+ @ 10,000-11,000 nm
Optical Density: is a measure of the transmittance of an optical element for a given length at a given wavelength λ. The higher the optical density, the lower the transmittance of light at a specified waveleng. See the
ANSI Z136 for more information about OD and laser glasses.
VLT (Visible Light Transmission):
87%
VLT: The attenuation of light by a filter in the visible spectrum. VLT is determined in relation to standard illumination and evaluated according to the daylight-adapted (photopic) or night-adapted (scotopic) conditions descriped more in the
ANSI Z136.7 for Testing and
Labeling of Laser Protective Equipment. The lower the VLT, the less "visible" light is transmitted.
Laser glasses may affect the ability to see warning lights/signs or distinguis between colors.
View Through Laser Glasses Filter*:
Compatible Laser Systems and Wavelengths:
WARNING: THESE LISTED LASER SYSTEMS ARE COMPATIBLE BY WAVELENGTH ONLY. ALWAYS VERIFY YOUR LASER'S WAVELENGTH AND OPTICAL DENSITY REQUIREMENTS BEFORE PURCHASING LASER GLASSES.
CO2 10,600 nm
LSOs (Laser Safety Officer) need to consider working environments, viewing conditions and beam delivery systems when making assessments and determining the correct laser glasses , goggles, barriers, or windows to protect against potentially hazardous laser radiation. Do not operate lasers without correct protective equipment and training.
Frame 10 Laser Glasses Specifications
Laser Glasses Description:
Light weight polycarbonate fit-over style frame with wide field of view, adjustable temples, and high lens clarity.
Temple adjustment:
24˚ 139-159 mm (5 positions)
.
Laser Glasses Dimensions:
Height: 63.8 mm
Width: 155.3 mm
Length: 140-160 mm